Used to join 10mm tubing to the main body of the T piece, for the range of sampling heads. It simply clicks into position, the black ring is pressed to release the tubing from the connector.
-
This component is used when the system needs to be smoke tested. The threaded plug is removed, which allows the smoke generator to gain access to the system. Simply replace after use.
-
This component is used when the system needs to be smoke tested. The threaded plug is removed, which allows the smoke generator to gain access to the system. Simply replace after use.
-
Used to drain condensation from the system, the sight glass allows the operator to view the level of condensation in the system, and remove the threaded stopper to release the water. Simply replace after use.
-
Used to drain condensation from the system, the sight glass allows the operator to view the level of condensation in the system, and remove the threaded stopper to release the water. Simply replace after use.
-
The conical kit is mainly used in cold/chill stores to sample air. The T compression adapter allows the 10mm tubing to be clicked into place, or removed by pushing on the black ring.
-
Used at the end of a pipe run to sample air, this product has the advantage of having a compression adapter, which is used to join the pipe to the 10mm tubing by clicking into position, or removing by pushing down on the black ring.
-
Used mainly in office blocks, the socket compression adapter offers a simple way of attaching the 10mm tubing to the 25mm pipe, by simply clicking it into place and removing it by pressing down on the black ring.
-
Used at the end of a pipe run, where air sampling is still required. The compression adapter is simple to use, by pushing the 10mm tubing into the adapter housing until a click is heard, confirming it is located, it can easily be removed by pushing down on the black ring.
-
The adapter is used to join the 10mm tubing to the body of the T piece, simply push the tube into the adapter until it clicks in position. It can be removed by pushing on the black circular ring.
-
The flush end kit is used at the end of a pipe run to sample air. This product has the advantage of having a compression adapter, which is used to join the 25mm pipe to the 10mm nylon tubing by clicking into position, or as required pushing on the black ring to remove.
-
This component is used to isolate certain area’s of the pipe run if required, pipe can be attached on one side only using the union.
-
This component is used to isolate certain area’s of the pipe run if required, pipe can be attached on both sides using the unions
-
This is a Non Return Valve, used when the system is being cleaned, preventing dust from returning to certain area’s of the pipe run.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere which can be measured and recorded, which can be drained on a regular basis by simply opening the valve.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere which can be measured and recorded, which can be drained on a regular basis by simply opening the valve.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere which can be measured and recorded, which can be drained on a regular basis by simply opening the valve.
-
Fire collars are designed to maintain the integrity and the fire resistance level of a building element where building service penetrations pass through. They stop heat, smoke, fire and gas moving between compartments of a building. In the event of a fire, the plastic pipes will begin to melt. Due to the exposure of heat, the intumescent will expand and with the pressure exerted from the metal shell, the intumescent will seal the hole left behind. This prevents the fire and smoke spreading to the next compartment and reinstates the fire resistance of the wall or floor.
-
Hardwearing tool for neat cuts in Bisson 25mm pipe, Complete with a V shaped long lasting blade, made from high carbon steel, which reduces tube deformation. Featuring comfportable handle, without a return spring for ease of use.
-
The 3 way valve is used for shutting off and allowing the flow of air in a piping system. This is mainly used when isolating the system during the blow off process.
-
Sold either as part of the flush sampling kit (ABS019F) or individually, it is used when sampling is required through a ceiling tile. It is the perfect solution when differing hole sizes are required in the same pipe run. The head features a standard 10mm central hole, into which can be inserted a choice of 8 jets with different sizes of sampling hole including: 2.0/2.5/3.0/3.5/4.0/4.5/5.0/5.5/6.0mm The required size jet is simply twisted off the strip and push fit into the head (no cement required)
-
Sold either as part of the flush sampling kit (ABS019F) or individually, it is used when sampling is required through a ceiling tile. It is the perfect solution when differing hole sizes are required in the same pipe run. The head features a standard 10mm central hole, into which can be inserted a choice of 8 jets with different sizes of sampling hole including: 2.0/2.5/3.0/3.5/4.0/4.5/5.0/5.5/6.0mm The required size jet is simply twisted off the strip and push fit into the head (no cement required)
-
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere, the water collects in the bottom of the clear plastic tube, which can be drained at will. For potential larger water volumes the condensation trap should be used.
-
Designed for changing the direction of a pipe run through 90 degree's on an aspirating smoke detection pipe network. Pipe is designed for aspirating fire detection only.
-
Designed for changing the direction of a pipe run through 45 degree's on an aspirating smoke detection pipe network. Pipe is designed for aspirating fire detection only.
-
Used for breaking a section of aspirating smoke detection pipe network for maintenance purposes. This device is designed for aspirating fire detection only.
-
Connects two pieces of aspirating smoke detection pipe of different sizes 25mm to 27mm (Vice versa). This devise is designed for aspirating fire detection only.
-
Connects two pieces of aspirating smoke detection pipe together. This device is designed for aspirating fire detection only.
-
This device is used when a "Bull nose" or "Side tee" flow split is required. This device aspirating fire detection only/
-
3 Meter PVC 25mm aspirating smoke detection pipe EN54 - 20 Approved. Pipe is designed for aspirating fire detection only.
-
Used when a 25mm connection is required to 10mm OD nylon tubing. To create a trunk adapter or a capillary end cap.
-
Used when sampling is required in a chill or coldstore. The conical head prevents ice or condensation from covering the sampling hole.
-
This Component is used when sampling in a chilled or cold store Environment. The capillary end cap is fuxed to one end of the pipe run, followed by a 2 meters of capillary 10mm OD nylon tube which links to the conical sampling head which is specifically designed to operate in a chilled or cold stores. If ice were to form on the sampling head it forms on the beak, and does not cover the sampling hole allowing the system to continue to function normally.
-
Used when the aspirating pipework is above a suspended ceiling, the flush head is fixed to the ceiling tile with the supplied nut and linked to the pipework using a two meter length of 10mm OD tubing and a capillary T piece which links into the pipe.