This component is used when it is necessity to sample through a suspended ceiling. The capillary end cap fits onto the end of the pipe run. There is then a 2 meter 10mm OD nylon tube which links into the flush sampling head, which is fixed by a nylon nut/washer to the ceiling tile.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary Tee piece fits onto the pipe run. There followed by a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary end cap fits onto the end of the pipe run. There is then a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
The capillary end cap is used when it is necessary to sample air not only in the pipe run, but also at the end of the pipe run. It fits directly onto the end of the 25mm pipe. There is a 10mm hole in the end cap, which attaches normally to a 10mm OD nylon tube of a pre-determined length to which it is possible to attach either a discrete flush or a conical sampling head.
-
Used when the system has to be periodically tested. Simply remove the protection cap. Test and replace.
-
Used to connect the aspirating pipe to 10mm OD flexible nylon tubing.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion ressistant, smooth inside and outside.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion resis tan t, smooth inside and outside.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion resistant, smooth inside and outside.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere which can be measured and recorded, which can be drained on a regular basis by simply opening the valve.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere, the water collects in the bottom of the clear plastic tube, which can be drained at will. For potential larger water volumes the condensation trap should be used.
-
-
Designed for changing the direction of a pipe run through 90 degree's on an aspirating smoke detection pipe network. Pipe is designed for aspirating fire detection only.
-
Designed for changing the direction of a pipe run through 45 degree's on an aspirating smoke detection pipe network. Pipe is designed for aspirating fire detection only.
-
Used for breaking a section of aspirating smoke detection pipe network for maintenance purposes. This device is designed for aspirating fire detection only.
-
Connects two pieces of aspirating smoke detection pipe of different sizes 25mm to 27mm (Vice versa). This devise is designed for aspirating fire detection only.
-
Connects two pieces of aspirating smoke detection pipe together. This device is designed for aspirating fire detection only.
-
This device is used when a "Bull nose" or "Side tee" flow split is required. This device aspirating fire detection only/
-
3 Meter ABS 25mm aspirating smoke detection pipes EN54 - 20 Approved. Pipe is designed for aspirating re detection only.
-
Used when a 25mm connection is required to 10mm OD nylon tubing. To create a trunk adapter or a capillary end cap.
-
This Component is used when sampling in a chilled or cold store Environment. The capillary end cap is fuxed to one end of the pipe run, followed by a 2 meters of capillary 10mm OD nylon tube which links to the conical sampling head which is specifically designed to operate in a chilled or cold stores. If ice were to form on the sampling head it forms on the beak, and does not cover the sampling hole allowing the system to continue to function normally.
-
Used when sampling is required in a chill or coldstore. The conical head prevents ice or condensation from covering the sampling hole.
-
This component is used when it is necessity to sample through a suspended ceiling. The capillary end cap fits onto the end of the pipe run. There is then a 2 meter 10mm OD nylon tube which links into the flush sampling head, which is fixed by a nylon nut/washer to the ceiling tile.
-
Used when the aspirating pipework is above a suspended ceiling, the flush head is fixed to the ceiling tile with the supplied nut and linked to the pipework using a two meter length of 10mm OD tubing and a capillary T piece which links into the pipe.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary Tee piece fits onto the pipe run. There followed by a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary end cap fits onto the end of the pipe run. There is then a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
Used when the system has to be periodically tested. Simply remove the protection cap. Test and replace.
-
The capillary end cap is used when it is necessary to sample air not only in the pipe run, but also at the end of the pipe run. It fits directly onto the end of the 25mm pipe. There is a 10mm hole in the end cap, which attaches normally to a 10mm OD nylon tube of a pre-determined length to which it is possible to attach either a discrete flush or a conical sampling head.
-
Used to connect the aspirating pipe to 10mm OD flexible nylon tubing.
-
Used when the system has to be periodically tested. The capillary Tee piece is installed in the pipe run at the easily accessible position. It has a removable protection cap which fits over the nylon tubing when the system is being used normally. When testing is required simply remove the protective cap, test and replace once completed.
-
Used when the system has to be periodically tested. The capillary tee piece is installed in the pipe run, and fitted with the necessary size of Sampling Point Adaptor. Sizes are available from 2-8mm in 0.5mm increases to enable the system to function normally. When the system has to be tested simply remove the Sampling Point Adaptor and test the system normally, replacing the jet when the test is complete.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion ressistant, smooth inside and outside.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion resis tan t, smooth inside and outside.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion resistant, smooth inside and outside.
-
The stainless steel flush sampling head is used in conjunction with the capillary T piece and 10mm nylon tubing, to form a flush sampling kit. It replaces the normal flush polypropylene head, it is used in harsh industrial environments, or in prisons where the prisoners occasionally block the 2mm central hole to set fire to their cells. This head features a discrete sampling hole that is not visible from the exterior of 3mm. This continues to sample the air if the central
hole is obstructed.