When pipe is installed in a manufacturing environment, dust and debris can build up in the pip run chich reduces the airflow and effectiveness of the dectector.
-
-
Used to connect the aspirating pipe to 10mm OD flexible nylon tubing.
-
The capillary end cap is used when it is necessary to sample air not only in the pipe run, but also at the end of the pipe run. It fits directly onto the end of the 27mm pipe. There is a 10mm hole in the end cap, which attaches normally to a 10mm OD nylon tube of a pre-determined length to which it is possible to attach either a discrete flush or a conical sampling head.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary end cap fits onto the end of the pipe run. There is then a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary Tee piece fits onto the pipe run. There followed by a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
Used when the system has to be periodically tested. The capillary Tee piece is installed in the pipe run at the easily accessible position. It has a removable protection cap which fits over the nylon tubing when the system is being used normally. When testing is required simply remove the protective cap, test and replace once completed.
-
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion ressistant, smooth inside and outside.
-
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion resis tan t, smooth inside and outside.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere which can be measured and recorded, which can be drained on a regular basis by simply opening the valve.
-
This Component is used when sampling in a chilled or cold store Environment. The capillary end cap is fuxed to one end of the pipe run, followed by a 2 meters of capillary 10mm OD nylon tube which links to the conical sampling head which is specifically designed to operate in a chilled or cold stores. If ice were to form on the sampling head it forms on the beak, and does not cover the sampling hole allowing the system to continue to function normally.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere, the water collects in the bottom of the clear plastic tube, which can be drained at will. For potential larger water volumes the condensation trap should be used.
-
-
-
-
-
-
Sold either as part of the flush sampling kit (ABS019F) or individually, it is used when sampling is required through a ceiling tile. It is the perfect solution when differing hole sizes are required in the same pipe run. The head features a standard 10mm central hole, into which can be inserted a choice of 8 jets with different sizes of sampling hole including: 2.0/2.5/3.0/3.5/4.0/4.5/5.0/5.5/6.0mm The required size jet is simply twisted off the strip and push fit into the head (no cement required)
-
Hardwearing tool for neat cuts in Bisson 25mm pipe, Complete with a V shaped long lasting blade, made from high carbon steel, which reduces tube deformation. Featuring comfportable handle, without a return spring for ease of use.
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere, the water collects in the bottom of the clear plastic tube, which can be drained at will. For potential larger water volumes the condensation trap should be used.
-
Sold either as part of the flush sampling kit (ABS019F) or individually, it is used when sampling is required through a ceiling tile. It is the perfect solution when differing hole sizes are required in the same pipe run. The head features a standard 10mm central hole, into which can be inserted a choice of 8 jets with different sizes of sampling hole including: 2.0/2.5/3.0/3.5/4.0/4.5/5.0/5.5/6.0mm The required size jet is simply twisted off the strip and push fit into the head (no cement required)
-
Used in an environment where there are constant temperature changes, which causes condensation in the system, typically in a chill store or a room that is open to the atmosphere which can be measured and recorded, which can be drained on a regular basis by simply opening the valve.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion resis tan t, smooth inside and outside.
-
Soft PVC hose with embedded steel wire reinforcement. Very flexible, strong, abrasion ressistant, smooth inside and outside.
-
Used when the system has to be periodically tested. The capillary Tee piece is installed in the pipe run at the easily accessible position. It has a removable protection cap which fits over the nylon tubing when the system is being used normally. When testing is required simply remove the protective cap, test and replace once completed.
-
Used to connect the aspirating pipe to 10mm OD flexible nylon tubing.
-
Used when the system has to be periodically tested. Simply remove the protection cap. Test and replace.
-
The capillary end cap is used when it is necessary to sample air not only in the pipe run, but also at the end of the pipe run. It fits directly onto the end of the 25mm pipe. There is a 10mm hole in the end cap, which attaches normally to a 10mm OD nylon tube of a pre-determined length to which it is possible to attach either a discrete flush or a conical sampling head.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary end cap fits onto the end of the pipe run. There is then a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
This component is used when it is necessary to sample through a suspended ceiling. The capillary Tee piece fits onto the pipe run. There followed by a 2 meter 10mm OD nylon tube which links into the discrete head. The discrete cap is supplied with a solid head, which will necessitate a hole being drilled to the required size by the installer. The discrete end cap is held in place by a hole in the ceiling tile.
-
This component is used when it is necessity to sample through a suspended ceiling. The capillary end cap fits onto the end of the pipe run. There is then a 2 meter 10mm OD nylon tube which links into the flush sampling head, which is fixed by a nylon nut/washer to the ceiling tile.